FS#5352 — FS#9274 — vac2-10-tms
Attached to Project— Anti-DDoS
Incident | |
Paris DC1 | |
CLOSED | |
![]() |
We had a problem on the Arbor
TMS 4000 box of VAC2 last week.
One of the mitigation cards
is dead and we are waiting for
the replacement:
http://status.ovh.co.uk/?do=details&id=5335
The 2 remaining cards are visibly not in the
best condition. We have just shut down VAC2.
TMS Fault
Appliance: vac2-10-tms
Subhost 'apm-0-0' is 'Inactive'
We are looking into the problem with Arbor but
card 0 seems dead as well as the 2nd...
Date: Wednesday, 11 September 2013, 00:28AMTMS 4000 box of VAC2 last week.
One of the mitigation cards
is dead and we are waiting for
the replacement:
http://status.ovh.co.uk/?do=details&id=5335
The 2 remaining cards are visibly not in the
best condition. We have just shut down VAC2.
TMS Fault
Appliance: vac2-10-tms
Subhost 'apm-0-0' is 'Inactive'
We are looking into the problem with Arbor but
card 0 seems dead as well as the 2nd...
Reason for closing: Done
apm-0-0- has refused to recover with gentler measures.
..
The latest attempt to restart apm-0-0 appears to have succeeded.
..
apm-0-0 crashed again after restart.
..
Looks like the appliance reboot was able to recover this TMS 4000.
All appears to be functioning correctly at this time.
We are seeing how to reinstall the profiles on the TMS
that rebooted without doing a STOP START on them.
We have put VAC2 back in production.
The box crashed again.
TMS Fault
Appliance: vac2-10-tms
Subhost 'apm-0-1' is 'Inactive'
The APM-E blade is failing to boot correctly.
We will request an RMA of the APM-E blade.
We rebooted the chassis with an APM card
that we received as an RMA.
TMS Fault
Appliance: vac2-10-tms
Subhost 'apm-0-1' is 'Inactive'
The new APM card crashed. It will be the chassis ..
We have found a bug in the in the naming of cards
between the chassis, the Arbor documentation and the
SHELL commands output.
We've just replaced the cards again.
We have restored the traffic.
The tracking of card n° written on the chassis and
in the system is not the same. When the card in
slot 3 (CLI) must be changed, the card is slot 2
(phsyical) must be withdrawn.
Totally illogical. We will put labels on the
chassis so that tracking is the same between the
CLI and the physical.
==================
The mapping of Slot Number (physical labeling) and that shown by CLI commands for TMS-4000 series is as below:
Slot Number Physical Labeling
Shelf Manager
0 MCM
1 PSM
2 APM
3 APM
4 APM
5 APM
Slot Number CLI (/ system hardware)
0 Shelf Manager
1 MCM
2 PSM
3 APM
4 APM
5 APM
6 APM
The chassis seems stable.
We will add the 3rd card. We are shutting down VAC2.
We have reset the box. It is stable.