OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
FS#9500 — vac-0-a9
Scheduled Maintenance Report for Network & Infrastructure
Completed
We need to install an SMU on ASR9. It fixes a port
bug which passes to \"down\" thus, we do not know why.

VAC2:
RP/0/RSP0/CPU0:vac2-0-a9(admin)#upgrade hw-module fpd all location 0/0/CPU0
Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Current Upg/Dng
Location Type Subtype Upg/Dng Version Version
=========== ==== ======= ======= =========== =========
0/0/CPU0 lc fpga2 upg 1.17 1.18
------------------------------------------------------
FPD upgrade in progress. Max timeout remaining 89 min.
FPD upgrade in progress. Max timeout remaining 88 min.
FPD upgrade in progress. Max timeout remaining 87 min.
Successfully upgraded fpga2 for ASR9001-LC on location 0/0/CPU0 from 1.17 to 1.18


FPD upgrade has ended.

RP/0/RSP0/CPU0:vac2-0-a9#hw-module location 0/0/CPU0 reload
Fri Oct 11 12:53:44.691 UTC
WARNING: This will take the requested node out of service.
Do you wish to continue?[confirm(y/n)]y
RP/0/RSP0/CPU0:vac2-0-a9#


Update(s):

Date: 2013-10-13 06:27:45 UTC
Done.

Date: 2013-10-13 06:27:33 UTC
Now moving to VAC1

Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Current Upg/Dng
Location Type Subtype Upg/Dng Version Version
=========== ==== ======= ======= =========== =========
0/0/CPU0 lc fpga2 upg 1.17 1.18
------------------------------------------------------
FPD upgrade in progress. Max timeout remaining 89 min.

Date: 2013-10-11 19:24:38 UTC
done

VAC1 remains. we'll deal with it early in the morning.

Date: 2013-10-11 17:08:08 UTC
VAC3:
Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Current Upg/Dng
Location Type Subtype Upg/Dng Version Version
=========== ==== ======= ======= =========== =========
0/0/CPU0 lc fpga2 upg 1.17 1.18
------------------------------------------------------
FPD upgrade in progress. Max timeout remaining 89 min.
FPD upgrade in progress. Max timeout remaining 88 min.
FPD upgrade in progress. Max timeout remaining 87 min.
Successfully upgraded fpga2 for ASR9001-LC on location 0/0/CPU0 from 1.17 to 1.18


FPD upgrade has ended.

RP/0/RSP0/CPU0:vac3-0-a9(admin)#
RP/0/RSP0/CPU0:vac3-0-a9#hw-module location 0/0/CPU0 reload
Fri Oct 11 18:27:27.734 CEST
WARNING: This will take the requested node out of service.
Do you wish to continue?[confirm(y/n)]y
Posted Oct 11, 2013 - 17:07 UTC